Follow us :

Load Cell IN-PW15AH 10 to 100kg C3 stainless steel Single Point weight force sensor for platform scale IP68 2.0±0.2mv/V

Load Cell IN-PW15AH 10 to 100kg C3 stainless steel Single Point  weight force sensor for platform scale IP68 2.0±0.2mv/V
group name
single point load cell
Min Order
1 piece
brand name
HUAZHUN
model
IN-PW15AH
payment method
L/C
update time
Thu, 21 Nov 2024 16:54:26 GMT

Paramtents

  • load cell type single point type

  • material stainless steel

  • capacity 10 to 100kg

  • Sensitivity 2.0±0.2

  • Accuracy C3 Multi Range (MR)

  • Input impedance 300 ... 500

  • Output impedance 330 ... 500

  • Zero balance 0±0.1

  • IP Rating IP68;IP69K

  • Application platform scale

Packging & Delivery

  • Min Order1 piece

Briefing

load cell factory in China,Single Point Load Cell,Stainless steel Load Cell,Different cable lengths and other options available

Detailed

IN-PW15AH 10 to 100kg Single Point Load Cell 
for platform scale
interchangeable with Vishay HBM,Mettler Toledo Load cell
Good quality and long life with competitive price!
Stainless Steel C3 weighing load cell


Special features
- Hermetically sealed(IP68; IP69K)
- highest reliability
- Reduced minimum load cell verification interval(V min) for multi range applications
- Interchangeable to products of many manufacturers
- Stainless steel
- 6-wire-technology
- Integrated connection for protective cable conduit systems



Type

PW15AH

Accuracy class1)

C3 Multi Range (MR)

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

10

20

50

100

Minimum LC verification interval

g

1

2

5

10

Temperature effect on

zero balance

% v.

Cn /

10 K

 

±0.0140

±0.0140

±0.0140

±0.0140

Max. platform size

mm

500 x 400

Sensitivity (Cn)

mV/V

2.0±0.2

Zero balance

0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

300 ... 500

Output resistance (R0)

330 ... 500

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

1...12

Max. excitation voltage

15

Insulation resistance (Ris) at 100 VDC

1

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL ),

% of

Emax

150

at max. eccentricity

mm

160

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Deflection at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

1.0

Protection class according to

EN 60 529 (IEC 529)

 

IP68(test conditions 100 h at 1m water column);IP69K(water at high presure,steam jet cleaning)

Material: Measuring element

Coating

Cable sheath

 

C1.4545

Silicone rubber

                                                                   PVC